Carbon monoxide is an invisible, odorless gas produced when fuel burns. A mobile kitchen can expose workers to exhaust from a generator, vehicle engine or fuel-burning appliance. An open service window alone does not establish that the space is safe.
OSHA recommends avoiding fuel-burning equipment in enclosed or partially enclosed spaces, using appropriate ventilation and installing carbon monoxide alarms where exposure is possible.
REVIEW THE ENTIRE SITE
Before service, consider exhaust from neighboring vendors as well as your own equipment. A generator that seemed well positioned in an empty parking lot may be beside another truck's air intake once the event opens. Follow equipment instructions and applicable fire rules, and ask the venue to keep designated equipment areas clear.
Portable generators must be operated outdoors, away from openings, according to the manufacturer's instructions. Permanently installed equipment needs professional installation and review. Never use a portable generator inside a truck, tent or other partially enclosed structure.
PREPARE THE CREW
- Ask a qualified professional to assess ventilation and exhaust routing.
- Install and maintain suitable alarms according to applicable rules and manufacturer instructions.
- Review the location of nearby engines and generators at each venue.
- Teach staff to recognize headache, dizziness, nausea and unusual weakness as possible exposure symptoms.
- Assign a person to contact emergency services and account for everyone outside.
IF AN ALARM SOUNDS
Stop service and get everyone into fresh air immediately. Call emergency services from a safe location, particularly if anyone has symptoms. Do not reenter until emergency personnel say it is safe. Do not silence an alarm and continue cooking.
For example, if two employees suddenly develop headaches during a winter lunch shift, treat the shared symptoms as a possible exposure rather than assuming both are tired. Suspend operations and have the equipment and environment evaluated before reopening.