Shore power allows a mobile kitchen to use an approved electrical supply provided by a venue. Before accepting a booking, confirm that the venue can support the truck's actual equipment and that the connection is suitable for the installation.
PREPARE A LOAD LIST
Copy the voltage, current and other electrical ratings from each appliance's nameplate. Include refrigeration, water heating, ventilation, beverage equipment and lighting. A qualified electrician should evaluate simultaneous loads, starting current, circuit protection and the connection configuration.
For illustration, a 1,500-watt appliance rated at 120 volts draws approximately 12.5 amps at that stated power. Adding two such appliances to a single 20-amp circuit would exceed that circuit's nominal rating even before other loads are considered. Actual equipment and code requirements determine what can operate safely.
Do not treat a receptacle's physical appearance as evidence that it can supply the required load.
QUESTIONS FOR THE VENUE
- What voltage, amperage and receptacle configuration are available?
- Is the supply dedicated to the unit or shared with other vendors?
- Where is the connection located relative to the approved parking space?
- Who confirms the installation and applicable protection requirements?
- What is the power fee, and what is the procedure if service fails?
Give the answers to your electrician or qualified equipment installer before the event.
CHECK THE CONNECTION BEFORE SERVICE
OSHA's electrical equipment rules address damaged cords, compatible plugs, grounding and equipment suitable for wet or conductive locations. Remove damaged equipment from service. Avoid improvising adapters, altering plugs or increasing protective device ratings to accommodate a load.
Compare site-power charges with the actual cost of an approved independent power arrangement, including fuel, maintenance and setup. Keep a written service contingency that protects food temperatures if power becomes unavailable.